Custom Search
 
  
 
TM 55-1905-223-24-18-2
3-254. REPLACE/REPAIR WELDED FITTINGS.
This task covers:
a. Removal
b. Repair
c. Replacement
INITIAL SETUP:
Tools
Equipment Condition
Tool kit, general mechanic's,
At Ship Service Switchboard, set MISC
MCHRY POWER PANEL circuit breaker
Torch outfit, cutting and
to OFF position. At Marine
welding medium duty, oxygen
Sanitation control module set
and acetylene, 3433-00-357-8116
main circuit breaker to OFF position.
Tool kit, welder, 5180-00-754-0661
Tag switches "Out of Service-Do Not
Operate."
Materials/Parts
All commodes tagged "Out of Service -
Do Not Operate."
Piping system, sewage and
plumbing, P/N 8528023 refer
General Safety Instructions
to TM 55-1905-223-24P
Warning tags, Item 1, Appendix C
Ensure system is turned OFF and
Utility pail, Item 13, Appendix C
tagged to prevent operation during
maintenance. Generated pressure
could cause injury.
WARNING
Toxic and flammable vapors are generated in the sewage system.
Provide ventilation from outside source before removing valves,
covers, drain plugs, hoses, and fittings. Avoid open flames
and prolonged breathing of fumes.
Use extreme care when breaking system connections. Escaping
pressure and/or fluids could cause injury.
Clean up spills immediately with disinfectant. Spills create
an unsafe working area.
After contact with sewage contaminated equipment, clean
yourself with disinfectant soap before performing hand-
to-mouth functions such as eating, drinking, smoking,
etc.
REMOVAL
Refer to paragraph 3-217 for procedures.
Change 1
3-731


 


Privacy Statement - Copyright Information. - Contact Us