Custom Search
 
  
 
TM 55-1905-223-24-2
i.
Remove the switch handle (10) and changeover lever (2 ).
1
j.
Remove the access cover (23).
k.
Remove the preformed packing (5 and 6), and discard.
l.
Remove the cap (1) and preformed packing (2).
m. Discard the preformed packing (2).
n. Remove the contamination switch (7).
o. Remove the preformed packing (8 and 9), and discard.
p. Remove the machine thread plugs (11) and retaining ring (12) from the filter head (14).
REPAIR
a. Check the filter head (14) for clear passages for fluid flow. Cleanwith solvent and a soft brush.
b. Check the changeover lever (21) for burrs, scoring, or other physical defects.
Smooth with crocus cloth as
required.
c.
Clean the fluid filter body (18) with solvent and a soft brush.
ASSEMBLY
a. Replace the retaining rings (12) and machine thread plugs (11) onto the filter head (14).
b. Install preformed packing (8 and 9).
c.
Replace the contamination switch (7).
d. Install the preformed packing (2) associated with the cap (1).
e. Replace the cap (1).
f.
Install the preformed packing (5 and 6).
g. Replace the access cover (23).
h. Replace the changeover lever (21) and switch handle (10). Secure with the straight headed pin (22).
i.
Replace the socket head screw (13).
j.
Install preformed packing (16 and 15).
k.
Replace the pipe nipples (17) and install filter element (20).
2-33


 


Privacy Statement - Copyright Information. - Contact Us