Custom Search
 
  
 
TM 55-1905-223-24-3
Table 2-1. Preventive Maintenance Checks and Services
D-Daily
M-Monthly
Q-Quarterly
A-Annually
B-Biennially
E-Every 1600 Operating Hours
Item
Interval
Items To Be
No.
DM
Q
A
B
E
Inspected/Serviced
Procedures
24
Cooling System-
cleaned and flushed. Refer to TB-55-1900-207-24.
CONT
continued
Drain the engine block by opening the drain valve
(petcock) located just above the starting motor.
Remove the thermostat housing in accordance with
Check for rust and scale on thermostat housing
components.
Refer to para. 2-28 for cleaning, repair, and
replacement procedures.
NOTE
Install a new pre-charge (DCA) type
filter element before filling the
system. Refer to Item 19 of this
table.
Fill the system. Refer to TB 55-1900-207-24.
25
Safety Controls
NOTE
Engine safety controls should be
hooked up to a horn or other
warning device.
Check the High Water Temperature Control.
a.
Remove the sensing unit and check the opening
or the circuit against a thermometer immersed
in water.
2-17


 