Table 2-2. Troubleshooting-Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
47. Engine cranks too quickly causing automatic trip valve to trip before engine starts.
STEP 1.
Check if air inlet pressure is too high.
Reduce inlet pressure in 10 psig increments until successful engine start.
48. Air starter continues to operate after control valve shutoff.
STEP 1.
Check if relay valve is sticking.
Replace relay valve (para. 2-24).