(e) Connect all wiring connections on the governor control (2). Remove tags.
(3) Replace the terminal board (21, Figure 2-6) as follows:
(a) Tag and disconnect wires from terminal strips.
(b) Unplug wiring harnesses.
(c) Remove four self-locking nuts (19) and flat washers (20) securing the terminal board to the
instrument cabinet (22) and remove the terminalboard.
(d) Position the new terminal board (21, Figure 2-6) in the instrument cabinet (22) and install
self-locking nuts (19) and flat washers (20). Secure self-locking nuts (19).
(e) Plug in wiring harnesses to their proper locations on the terminal board (21). Connect all
wiring and secure. Remove tags.
REPLACEMENT
a. Install the instrument bracket (23) with screws (27) and nuts (28), if removed.
b. Position the instrument cabinet (22) with mounts (29 to the bracket (22) and install resilient mounts
)
(26), flat washers (24), and nuts (25). Tighten the nuts.
c.
Run unharnessed wiring through their proper conduits in the bottom of the instrument cabinet (22) and
reconnect. Plug wiring harnesses (11, 31) and electrical power cable assembly (30) to their proper
locations on the bottom of the cabinet (22) and tighten. Remove tags.
d. Close the front panel (2) by swinging it upward and tighten the screws in top corners.
2-63


 