Custom Search
 
  
 
TM 55-1905-223-24-3
j. Connect battery banks (starboard), operate air supply (port), refer to TM 55-1905-223-10.
k. Operate the engine until it reaches a temperature of 180 (80 ) and check for leaks.
F
C
l. With the engine running, use a multimeter to check the magnetic pickup voltage at the governor
control inside the instrument panel (paragraph 2-26). If voltage is less than 1.5 volts ac, loosen the
locknut on the magnetic pickup (12, Figure 3-62) and screw it in clockwise 1/8 to 1/4 turn.
3-130


 