d. Inspect the air intake piping for obstructions, corrosion, and dents.
REMOVAL
a. Remove hose clamps (1, 13) at the air inlet metallic tube (11) and preformed hose (12).
b. Remove nonmetallic elbow (2) and metallic tube (11).
c. Remove bolts (9), nuts (7) and washers (8) in the air cleaner straps (3) on each side of the assembly.
d. Remove air cleaner (5).
e. Remove air cleaner inlet cap (4) and filter cap (6).
f. Remove air filter element (10).
g. Unscrew and remove filter warning indicator (14).
REPAIR
Repair to the air cleaner is by replacement of the intake filter element (10), preformed hose (12), and filter
warning indicator (14).
REPLACEMENT
a. Insert the clean or new element (10) into the air cleaner (5), making sure that it seats properly on the
gasket end.
b. Install the air cleaner inlet and filter caps (4, 6).
c. Install metallic tube (11) and nonmetallic elbow (2).
d. Mount air cleaner unit with air cleaner straps (3) and install bolts (9), nuts (7), and washers (8).
e. Connect the air cleaner (5), nonmetallic elbow (2) and air inlet metallic tube (11) and preformed hose
(12) with hose clamps (1, 13).
f. Install filter warning indicator (14).
2-72


 