2-11. Replace Followup Unit. (FIGURE 2-2)
This task covers:
a. Removal,
b. Replacement.
INITIAL SETUP
Tools
Equipment Condition
Tool kit, general mechanic's,
Equipment shut down and tagged
"Out of Service - Do Not Operate."
Tool kit, electrician's,
See TM 55-1905-223-10.
Materials/Parts
Followup unit, P/N 510-006
REMOVAL
a.
Tag and remove three cable connectors (6) from unit.
b.
Loosen capscrew (2) connecting gear arm (3) to followup unit (1).
c.
Lift gear arm (3) and spring post (4) off straight shaft (5).
d.
Remove four mounting bolts and washers (7, 8).
e.
Remove followup unit (1) from mounting bracket (9).
REPLACEMENT
a.
Position followup unit (1) over mounting bracket (9) with bolt holes aligned.
b.
Install and secure four mounting bolts and washers (7, 8).
c.
Install spring post (4) and gear arm (3) on straight shaft (5); secure capscrew (2).
d.
Install three cable connectors (6) as tagged.
e.
Remove "Out of Service - Do Not Operate" tag and restore unit to operation.