Custom Search
 
  
 
TM 55-1905-242-14
0015 00
KVH MV103 DIGITAL COMPASS
136. F1 3/10A
Fuse under screw-off cap. Fuse protects the compass from short circuits
137. POWER
Controls power to the compass. OFF, no power applied; ON, applies
power to the compass but not to the display lighting; LIGHT ON, applies
lighting to the display.
138. DIMMER
Controls the display lighting when POWER is at LIGHT ON.
139. DECL.
Used to enter declination to convert magnetic to true North and to enter
sensor alignment correction factor.
140. GPS/NAV
Used to toggle between compass heading and GPS input display modes.
141. RESPONSE
Adjusts display response time (damping factor). SLOW, averages value
over 17-second period. MED, averages value over a 9-second period.
FAST, averages value over a 3-second period.
142. SET CRS
Used to enter a reference course or a sensor alignment correction factor.
Also used to start calibration.
136
3 / 10A SB
MV103 DIGITAL COMPASS
F1
KVH INDUSTRIES MIDDLETOWN RI USA
LIGHT
ON
CAL (HOLD DOWN)
SLOW
+
F
EAST
ON
MED
WEST
FAST
OFF
SET
GPS/
POWER
DECL.
CRS
RESPONSE
NAV
DIMMER
140
139
138
137
142
141
0015 00-18


 