Custom Search
 
  
 
TM 55-1905-242-14
0016 00
24 VDC POWER DISTRIBUTION PANEL
15.
COMMAND & CONTROL D/B
These fuses protect the feed between the 24 Vdc power distribution panel
FUSES 63A
and the command and control distribution box from damage due to over-
load.
16.
CONTROL & DISTRIBUTION
These fuses protect the feed between the 24 Vdc power distribution panel
FUSES 100A
and the control and distribution panel from damage due to overload.
17.
COMMS NAVAID D/B FUSES
These fuses protect the feed between the 24 Vdc power distribution panel
63A
and the comms nav aid distribution box from damage due to overload.
18.
STBD ENGINE CIRCUIT FUSE
This fuse protects the starboard engine starting and alternator excitation
10A
circuits from damage due to overload.
19.
COMMS NAV AID D/B BATTERY
This switch permits the operator to select which battery bank will supply
SELECTOR SWITCH
the comms nav aid distribution box. In the PORT position, the port battery
bank is selected. In the STBD position, the starboard battery bank is
selected.
20.
STBD BATTERY ISOL SWITCH
This switch permits the operator to isolate the starboard battery bank.
When ON is selected, the starboard battery bank is available for use. In
this position, the battery selector switches (Comms Nav Aid D/B, Control
& Distribution, and/or Command & Control D/B) determine which panel or
distribution box is supplied by the starboard battery bank. When OFF is
selected, the battery bank is isolated and will power nothing.
21.
PORT BATTERY ISOL SWITCH
This switch permits the operator to isolate the port battery bank. When
ON is selected, the port battery bank is available for use. In this position,
the battery selector switches (Comms Nav Aid D/B, Control & Distribu-
tion, and/or Command & Control D/B) determine which panel or distribu-
tion box is supplied by the port battery bank. When OFF is selected, the
battery bank is isolated and will power nothing.
22.
CONTROL & DISTRIBUTION
This switch permits the operator to select which battery bank will feed the
BATTERY SELECTOR SWITCH
control & distribution panel. In the PORT position, the port battery bank
is selected. In the STBD position, the starboard battery bank is selected.
23.
COMMAND & CONTROL D/B
This switch permits the operator to select which battery bank will supply
BATTERY SELECTOR SWITCH
the command & control distribution box. In the PORT position, the port
battery bank is selected. In the STBD position, the starboard battery bank
is selected.
24.
PORT ENGINE CIRCUIT FUSE
This fuse protects the port engine starting and alternator excitation cir-
10A
cuits from damage due to overload.
0016 00-4


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business