BATTERY CHARGER
25.
DC VOLTS
This voltmeter shows voltage output of charger measured in Volts, direct
current.
26.
DCAMPERES
This ammeter shows the current output of charger measured in amperes.
27.
EQUALIZE/FLOAT Switch
This switch permits the operator to select between EQUALIZE and FLOAT
modes. When EQUALIZE is selected, the charger operates at a high
charging rate to recharge the batteries or to support the load applied to the
batteries by the vessel's 24 Vdc systems. When FLOAT is selected, the
charger maintains a "trickle" charge to keep the batteries charged during
periods of inactivity.
28.
FLOAT Potentiometer
This permits adjustment of the FLOAT voltage level.
29.
EQUALIZE Potentiometer
This permits adjustment of the EQUALIZE voltage level.