TM 55-1905-242-14
0019 00
STARBOARD SEA CHEST SEACOCKS
24.
Air Conditioning Raw Water Cooling
Secures the raw water supply to the air conditioning raw water strainer
Seacock
and raw water pump. When the seacock is OPEN, raw water is allowed to
supply the strainer and pump. When the seacock is CLOSED, raw water is
secured to the system.
25.
Fire and Ballast Pump Raw Water
Secures the raw water supply to the fire and ballast pump. When the
Seacock
valve is OPEN, the pump is supplied with raw water through a strainer.
When the valve is CLOSED, raw water is secured to the system.
26.
Diesel Generator Raw Water Cooling
Secures the raw water supply to the diesel generator raw water cooling
Seacock
system. When the valve is OPEN, raw water is allowed to supply the
system's strainer and raw water pump. When the valve is CLOSED, the
raw water supply is secured.
24
25
26
DIESEL GENERATOR SIPHON BREAK OVERBOARD DISCHARGE VALVE
27.
Diesel Generator Siphon Break
Controls venting of the diesel generator siphon break. When the valve
Overboard Discharge Valve
is OPEN, the siphon break is permitted to vent and the siphon break
operates. When the valve is CLOSED, the siphon break is deactivated.
The siphon break valve should remain OPEN except during damage con-
trol operations.
DIESEL GENERATOR
BATTERY BOX
27
0019 00-6
|
||