Tweet |
Custom Search
|
|
|
||
TM 55-1905-242-14
0019 00
OILY WATER PUMPING AND COLLECTION SYSTEM CONTROLS
45.
Oily Water Pressure Discharge Valve
Controls the flow of oily water at the pressure discharge fitting. This
valve is fed by the oily water pump. When the valve is OPEN, oily water
may be discharged at the pressure discharge fitting. When the valve is
CLOSED, oily water flow is secured. The valve is OPEN only when using
the oily water pump to discharge bilge and/or oily water to an approved
facility.
46.
Oily Water Suction Discharge Valve
Controls the flow of oily water at the suction discharge fitting. This valve
is used when the oily water tank is drained by a shore facility's pumping
unit. When the valve is OPEN, oily water may be drawn from the oil water
tank. When the valve is CLOSED, oily water flow is secured. The valve is
OPEN only when the oily water tank is being drained by a shore facility's
pump.
47.
Oily Water Suction Valves
Selects the suction source for the oily water pump. Depending upon the
alignment of the valves, oily water may be drawn from the bilge manifold,
from the oily water tank, or from the engine, transmissions, or buckets via
a suction hose. Operation of the system is described in WP 0026 00.
48.
Oily Water Discharge Valves
Selects the discharge route for the oily water pump. Depending upon the
alignment of the valves, oily water may be discharged to the oily water
tank or to the pressure discharge fitting.
49.
Oily Water Discharge Tank Sight
Indicates level of oily water present in the tank.
Gauge
VENT
46
45
49
47
48
FROM / TO OILY
WATER TANK
0019 00-13
|
||