TM 55-1905-242-14
0026 00
Pump Oily Water from Bilges (continued)
! CAUTION
Do not overfill the oily water discharge tank. Overfilling the tank can force oily water out
the tank vent.
9.
Continue to monitor the level of the oily water collection tank as the pumping proceeds. Do not overfill the tank.
Overfilling the tank can force oily water out the tank vent.
10. When pumping is completed, secure the pump by setting to OFF the OILY WATER DISCHARGE switch (43).
11. CLOSE valves 33, 36, and all compartment suction valves (34).
12. If no further pumping is necessary, set to OFF the OILY WTR BILGE PUMP circuit breaker (32).
43
WIPER
WIPER
WIPER
WASHER
FIRE
OILY
CRANE
FRESH
BLACK
PORT
CENTER
STBD
PUMP
WATER
DIVERT
WATER
WATER
CLUTCH
DISCHARGE
VALVE
PRESSURE
DISCHARGE
Pump Lube Oil from Engines and Marine Transmissions
Refer to illustrations in Pump Oily Water from Bilges procedure in this work package.
1.
Set to ON the OILY WTR BILGE PUMP circuit breaker (32), located in the control and distribution panel.
2.
OPEN the oily water collection pump lube oil suction valve (37).
3.
OPEN the oily water pump to tank valve (36).
4.
Ensure that valves 33, 38, 39, 40, and 41 are CLOSED.
5.
Connect the lube oil change system hose (44) to the desired engine or marine transmission.
6.
Check the oily water tank level at the sight glass (42) to ensure that the tank has adequate capacity to contain the lube
oil in the selected component.
7.
Begin pumping by setting to ON the OILY WATER DISCHARGE switch (43).
0026 00-10