Custom Search
 
  
 
TM 55-1905-242-14
0026 00
Pressurize the Potable Water System (continued)
2.
The pressure set is self-regulating and will maintain the potable water system pressure without operator attention.
3.
To shut down the potable water pressure set, set to OFF the FRESH WTR TANK PRESS SET circuit breaker (51).
065 20AF
084 20AF
093
20A
087
20A
064 20AF
070
20A
OILY WTR
ENG RM
SEARCH
BLK WTR
ENG RM
WIPERS
BILGE
VENT FAN
LT
DISC
VENT FAN
PORT &
PUMP
NO. 2
PUMP
NO. 1
CENTER
086
15A
092
15A
071
15A
083 10AF
077
15A
076
15A
ENG RM
NAV LTS
24 VDC
WIPERS
W/C
ENG RM
LTS PORT
PANEL
RCPTS
STBD &
PUMP
LTS
51
& LAZ
WASH
STBD
PUMP
5A
073
074
10A
5A
088
10A
082
10N
075
10A
072
WHITE LTS
WHITE
RED LTS
RED LTS
FRESH
PILOT
LTS
HORN
ACCOM
WTR TANK
PILOT
HOUSE
ACCOM
PRESS
CHART &
HOUSE
CHART &
SET
& W/C
COMPASS
COMPASS
080
5A
066
5A
090
5A
069
2.5A
081
5A
078
5A
FIRE
HYD
VENT FAN
ENGINE
VENT
WEATHER
PUMP
CRANE
BATTERY
ALARM
FAN
DECK
52
CLUTCH
DIVERT
COMP
PANEL
W/C
LIGHTS
VALVE
067 2.5A
068 2.5A
079
5A
085 2.5A
089 2.5A
103
15A
VENT FAN
VENT FAN
GEN
FIRE
RUDDER
RED
NO. 1
NO. 2
ALARM
DETECT
ANGLE
CARGO
ACCOM
ACCOM
SYSTEM
& TANK
LIGHTS
GAUGES
FUSES LOCATED
054 2.5A
055 2.5A
053
5A
BEHIND COVER
SPARE
SPARE
SPARE
Monitor Potable Water Tank Level
1.
To activate the potable water tank monitoring system, set to ON the RUDDER ANGLE & TANK GAUGES circuit breaker
(52), located in the control and distribution panel.
2.
To read the tank level, observe the potable tank level indicator (53) in the pilothouse. A green LED indicates a full tank,
a yellow LED indicates the tank at MID level, and a red LED indicates an empty tank.
3.
To shut down the potable water tank monitoring system, set to OFF the RUDDER ANGLE & TANK GAUGES circuit
breaker (52).
EMPTY
MID
FULL
TANKWATCH III
53
LEVEL
MONITOR
SYSTEM
0026 00-14


 