HEATING AND AIR CONDITIONING
1.
A 220 Vac power supply must be available via shore power or the diesel generator set. Refer to DIESEL GENERATOR
STARTUP in WP 0023 00 or SHORE POWER in this work package to supply the vessel with 220 Vac power.
2.
OPEN the heating/air conditioning raw water pump seacock (85).
85
3.
Set to ON the appropriate circuit breaker(s) (86) for the desired heating/cooling unit(s).
4.
Set the MODE knob (87) to the desired mode. In OFF, the unit is OFF. In FAN, only the fan blows, no heating or cooling
takes place. In RUN, output temperature is controlled by the thermostat.
5.
Set the FAN knob (88) to the desired fan speed.
6.
Set the THERMOSTAT knob (89) to the desired temperature.
7.
To secure the heating and air conditioning units, set to OFF the appropriate circuit breakers (86) for the desired heating/
cooling unit(s), and CLOSE the heating/air conditioning raw water pump seacock (85).
87
FAN
RUN
OFF
MODE
88
HI
R
FAN
89
C
R
THERMOSTAT
0026 00-31


 