Tweet |
Custom Search
|
|
|
||
TM 55-1905-242-14
0063 00
7
5
4
6
3
2
1
REPLACE--LIGHTING FIXTURE, INCANDESCENT
REMOVAL
WARNING
Replace or repair components only after the affected circuit has been secured, locked
out, and tagged out. Performing replacement with the circuit energized may result in
damaged equipment and serious injury or death to personnel.
1.
Unscrew and remove the guard (1) covering the light from the face plate assembly (6).
2.
Unscrew and remove the globe (2) from the face plate assembly (6).
3.
Unscrew and remove the light bulb (3) from the socket (4).
4.
Set the multimeter to the Vdc (Volts direct current) setting. Place one multimeter lead on the center electrode of the socket
(4) and one lead on the internal threads of the socket. If no voltage is noted, proceed to the next step. If voltage is noted,
ensure that the proper circuit breaker is properly secured.
0063 00-2
|
||