TM 55-1905-242-14
0085 00
INSTALLATION
1.
Procure a new hose, fitting, or pipe (3).
2.
Thread the swivel fitting (2) onto the fixed end of the piping, fitting, or hose (1).
3.
Tighten the fittings by placing one wrench on the swivel fitting (2) and one wrench on the fixed end of the piping, fitting,
or hose (1).
4.
Repeat steps 2-3 for the other end of the piping, fitting, or hose (1).
5.
Use a wiping rag to wipe clean the work area.
6.
Remove the lockouts and tagouts, and check the operation of the system.
7.
After checking the operation, visually inspect the work area for any signs of leakage and check the hydraulic fluid level
in the reservoir; replenish it as required.
8.
Dispose of used hydraulic fluid and contaminated materials in accordance with local regulations.
END OF WORK PACKAGE