TM 55-1905-242-14
0101 00
REMOVAL (continued)
3.
Label and disconnect the wiring from the input and output terminals.
4.
Remove the mounting bolt (4) and remove the transformer body (3) from the bulkhead.
INSTALLATION
1.
Position the transformer body (3) on the bulkhead and secure it with the mounting bolt (4).
2.
Connect the wiring to the input and output terminals using the labels from step 3 of Removal as a guide.
3.
Install the access cover (2) and secure it with the screws (1).
4.
Remove the lockouts and tagouts and check the operation of the system.
END OF WORK PACKAGE