INSTALLATION--ARRAY ASSEMBLY
24
25
26
27
15
28
32
31
30
29
1.
Ensure that the bitumen washers (38) are in place on the mount (37).
2.
Using two crewmembers, carefully lift the pedestal unit (14 and 15) into position on its mount (37).
3.
Secure the pedestal base (15) to the mount (37) with the studs (36), flat washers (35), lockwashers (34), and four nuts (33).
4.
Loosen the four self-retaining bolts (13) securing the pedestal lid (14) to the pedestal base (15). Pull each self-retaining
bolt up and turn it counterclockwise to lock them in the upright position.
5.
Open the pedestal lid (14), ensuring that the securing stay has automatically locked into position.
6.
Slide the wiring assembly (32) into the pedestal base (15) and secure it with the cable clamps (27 and 28), screws (24),
lockwashers (25), and flat washers (26).
7.
Slide the grommet (31) and washer (30) into the pedestal base (15) and secure them with the gland nut (29).
8.
Install the signal connector wiring (22) into the signal connector (21) using the labels from step 8 of Removal--Array
Assembly as a guide. Installation is accomplished by pressing the internal lock tab with a small screwdriver (23) while
inserting the appropriate wire.
9.
Install the wiring into the positive (16) and negative (17) terminals of the power connector (18) using the labels from step
6 of Removal--Array Assembly as a guide. Installation is accomplished by pressing the locking tabs (19) with a
screwdriver (20) while inserting the wire.
10. Close the pedestal lid (14) and secure it with the four self-retaining bolts (13).
11. Carefully lower the array (10) into position on the pedestal (11), taking care not to damage the coaxial mounting pin (12).
12. Secure the array (10) to the pedestal (11) with the studs (9), flat washers (8), lockwashers (7), and nuts (6).
13. Remove the lockouts and tagouts and check the operation of the system.