Tweet |
Custom Search
|
|
|
||
TM 55-1905-242-14
0124 00
3
1
5
7
8
6
9
4
2
13
14
12
11
10
NOTE
Cotter pins, lockwashers, locking nuts, and similar locking devices shall be discarded after removal and replaced with
new cotter pins, lockwashers, locking nuts and similar locking devices.
8.
Remove the three nuts (10), lockwashers (11), flat washers (12), and three bolts (13) that secure the base (2) to the mount
(14) and remove the base from the mount.
INSTALLATION--MASTHEAD/SIDE/NOT-UNDER-COMMAND LIGHT FIXTURE
1.
Position the base (2) on the mount (14) and secure it with three bolts (13), flat washers (12), lockwashers (11), and three
nuts (10).
2.
Install the wiring in the cable clamp assembly (9) and secure the cable clamp assembly to the base (2) with two screws (8).
3.
Connect the wiring to the bulb holder (6) using the labels from step 6 of Removal--Masthead/Side/Not-Under-Command
Light Fixture as a guide.
4.
Position the bulb holder (6) in the base (2) and secure it with the two screws (7).
5.
Install the bulb (5) into the bulb holder (6).
6.
Position the gasket (4) into the base (2), and then place the lens housing (3) into the base and secure it with the locking
ring assembly (1).
7.
Remove the lockouts and tagouts and check the operation of the system.
0124 00-2
|
||