Custom Search
 
  
 
TM 55-1905-242-14
0136 00
REMOVAL--TANK UNIT (continued)
2.
Set the multimeter to the Vdc (Volts direct current) setting and check for voltage across each of the wiring terminals (1)
on the tank unit (3). If no voltage is noted, proceed to the next step. If voltage is noted, ensure that the circuit breaker
is properly secured.
3.
Label and disconnect the wiring (2) from the wiring terminals (1).
4.
Unscrew the tank unit (3) from the tank (4).
INSTALLATION--TANK UNIT
1.
Adjust the probes (5) on the new tank unit (3) to the same level as the old unit. Ensure that the lowest level probe is set
as an "Empty Indicator" (6) and that the middle and highest probes are set as "Full Indicators" (7).
2.
Screw the tank unit (3) into the tank (4).
3.
Connect the wiring (2) to the wiring terminals (1) using the labels from step 3 of Removal--Tank Unit as a guide.