REMOVAL--ACCOMMODATION MODULE VENTILATION FAN
WARNING
Replace or repair components only after the affected circuit has been secured, locked
out, and tagged out. Performing replacement with the circuit energized may result in
damaged equipment and serious injury or death to personnel.
1.
Set to OFF, lock out, and tag out the VENT FAN NO.1 ACCOM or VENT FAN NO. 2 ACCOM circuit breaker in
accordance with FM 55-502.
2.
Remove the two screws (28) that secure the junction box cover (29) to the junction box (30), and remove the junction box
cover.
3.
Set the multimeter to the Vdc (Volts direct current) setting. Place one multimeter lead on each of the wiring connections
inside the junction box (30). If no voltage is noted, proceed to the next step. If voltage is noted, ensure that the circuit
breaker is properly secured.
4.
Label and remove the wiring (31) from the junction box (30).
5.
Remove the bolts (32) and washers (33) that secure the accommodation module ventilation fan (34) to the bulkhead.
INSTALLATION--ACCOMMODATION MODULE VENTILATION FAN
1.
Position the accommodation module ventilation fan (34) on the bulkhead and secure it with the bolts (32) and
washers (33).
2.
Connect the wiring (31) inside the junction box (30) using the labels from step 4 of Removal--Accomodation Module
Ventilation Fan as a guide.