INSTALLATION--BILGE STRAINER
1.
Wrap the threads on the piping (2) with antiseizing sealant tape.
2.
Screw the strainer (1) onto the piping (2).
3.
Install the void cover and terminate the confined space entry procedure.
REMOVAL--PIPING
1.
Remove the void cover from the desired void and prepare it for confined space entry in accordance with the Organiza-
tional Confined Space Entry SOP and FM 55-502.
2.
Loosen the hose clamps (3) that secure the hose (4) to the piping (5).
3.
Slide the hose (4) off the piping (5). Remove the piping as required.
INSTALLATION--PIPING
1.
Position the piping (5) in the void and place the hose (4) over the piping.
2.
Secure the hose (4) to the piping (5) with the hose clamps (3).
3.
Install the void cover and terminate the confined space entry procedure.
REMOVAL--VALVES
1.
Loosen the union halves (6) that secure the valve (7) to the piping (8) and the bilge manifold (9).
2.
Remove the valve (7) from the piping (8) and bilge manifold (9).
3.
Remove the union halves (6) from the valve (7).