TM 55-1905-242-14
0157 00
INSTALLATION
! CAUTION
The threaded ends of flared hydraulic fittings are not to be installed with the use of
antiseizing sealant tape or any other non-hydraulic sealant. Damage to hydraulic equip-
ment may occur.
1.
Procure new hose (2), valve (6), or fittings (3, 4, 5) as required.
2.
Wrap only the pipe threads of hydraulic fittings with antiseizing sealant tape prior to assembly. Do not use antiseizing
sealant tape or any other non-hydraulic sealant on the threads of flared hydraulic fittings.
3.
Reassemble the hose (2), valve (6), and/or fittings (3, 4, 5) in the reverse order of disassembly.
4.
Remove the lockouts and tagouts and check the operation of the system, ensuring that the hydraulic ramp performs
normally and that no leakage is noted.
5.
Replenish the ramp system hydraulic reservoir as required.
6.
Dispose of used hydraulic fluid, cleaning solvent, and contaminated materials in accordance with local regulations.
END OF WORK PACKAGE
01570157 00-3