Custom Search
 
  
 
TM 55-1905-242-14
0169 00
8
9
6
4
5
2
3
1
7
INSTALLATION
1.
Position the condensing unit on the deck and secure it with the bolts (8) and washers (9).
2.
Connect the refrigerant lines to the service valve fittings (7).
3.
Connect the raw water lines to the condenser fittings (6).
4.
Connect the wiring (5) inside the electrical box (4) using the labels from step 5 of Removal as a guide.
5.
Position the electrical box cover (3) on the electrical box (4) and secure it with the screws (2).
6.
Connect the manifold gauges and vacuum pump to the service valves (1) and draw the system into a vacuum. Allow the
system to remain in a vacuum for at least 15 minutes before proceeding.
7.
Remove the vacuum pump. Remove the lockouts and tagouts and charge the system with monochlorodifluorom
(refrigerant).
8.
Check the operation of the system. The output air should be noticeably cooler than the ambient air.
END OF WORK PACKAGE