Tweet |
Custom Search
|
|
|
||
TM 55-1905-242-14
0170 00
REMOVAL (continued)
8.
Remove the pump/hydraulic motor assembly from the engine room and place it on a suitable work bench.
9.
Plug and/or cap all open hydraulic lines to prevent contamination of the system.
INSTALLATION
1.
Position the pump/hydraulic motor assembly against the upright, and secure it with the four mounting bolts (12) and
nuts (13).
2.
Remove the plugs and/or caps from the hydraulic lines and reconnect the hydraulic lines to their fittings.
3.
Secure the suction hose (10) to the suction piping (11) with the hose clamps (9).
4.
Connect the bilge pump discharge piping (8) at the union (7).
5.
Connect the flow control valve (5) to the motor (6) with the union (4).
6.
Connect the hydraulic return line (1) to the discharge elbow (2) and the T connection (3).
7.
Remove the lockouts and tagouts and check the operation of the system, ensuring that the motor and pump operate
properly and that no hydraulic fluid or water leaks are present.
8.
Check the level of hydraulic fluid in the reservoir and replenish the hydraulic fluid as required.
9.
Dispose of used hydraulic fluid and contaminated materials in accordance with local regulations.
END OF WORK PACKAGE
0170 00-2
|
||