1.
Position the relief valve (3) under the console and connect the piping (1 and 2).
2.
Remove the lockouts and tagouts and adjust the relief valve (WP 0180 00).
3.
After adjusting the relief valve (3), check the operation of the system. Ensure that the helm operates normally and that
no leaks are present.
4.
Check the level of hydraulic fluid in the reservoir and replenish as required.
5.
Install the access panel below the helm.
6.
Dispose of used hydraulic fluid and contaminated materials in accordance with local regulations.