TM 55-1905-242-14
0187 00
ASSEMBLY
1.
Coat the spool bore of the valve body (6) with a light coat of clean hydraulic fluid.
2.
Install the spool (9) and spool spring (8) into the valve body (6). The tapered end of the spool (9) must be installed facing
the inlet port (10).
3.
Install the preformed packing (7) in the valve body (6).
4.
Position the cap (5) on the valve body (6) and secure it with the bolts (4).
INSTALLATION
1.
Wrap the male pipe threads on the inlet (1) and outlet (2) piping with antiseizing sealant tape.
2.
Connect the inlet (1) and outlet (2) piping to the check valve (3).
3.
Remove the lockouts and tagouts and check the operation of the system, ensuring that the ramp operates normally and
that no leakage is present.
4.
Check the hydraulic fluid level in the reservoir and replenish as required.
5.
Dispose of used hydraulic fluid, used cleaning solvent, and contaminated materials in accordance with local regulations.
END OF WORK PACKAGE
0187 00-3/4 blank
0187 00-3