Custom Search
 
  
 
TM 55-1905-242-14
0205 00
DC VOLTMETER OR DC AMMETER REPLACEMENT
1.
Remove the screws (14) that secure the recessed controls panel (15) to the cabinet. Remove the recessed controls panel (15).
2.
Label and remove the wiring (27) from the DC ammeter (28) or the DC voltmeter (29) as necessary.
3.
Remove the nuts (30) that secure the DC ammeter (28) or the DC voltmeter (29) to the recessed controls panel (15).
Remove the defective gauge.
4.
Position a new DC ammeter (28) or DC voltmeter (29) in the recessed controls panel (15) and secure it with the nuts (30).
5.
Connect the wiring (27) to the DC ammeter (28) or DC voltmeter (29) using the labels from step 2 of DC Voltmeter or DC
Ammeter Replacement as a guide.
6.
Position the recessed controls panel (15) on the cabinet and secure it with the screws (14).
27
27
28
30
29
30
15
FOLLOW-ON SERVICE
After completing the necessary repairs:
1.
Close the access door (2) and secure it with the screws (1).
2.
Remove the lockouts and tagouts, power up the battery charger, and check for proper operation.
END OF WORK PACKAGE