0038 00
RFSS-13 LIQUID LINE CRSVR CO
RFSS-20 SUCT LINE CRSVR COV
RFSS-47 RLF CONDSR
RFSS-52 COV-WTR RGLTR FREON
RFSS-53
RFSS-46 RLF-CONDSR
COV-WTR
WALK-IN FREEZER
CHILL BOX
RGLTR FREON
0 F
35 F
SEE DETAIL A
SEE DETAIL B
TO ATMOSPHERE
TO ATMOSPHERE
WATER
REEFER SPACE
REEFER SPACE
INLET
T
CONDENSING UNIT
CONDENSING UNIT
ASSY NO. 1
ASSY NO. 1
SEE DETAIL C
SEE DETAIL C
WATER REGULATING
WATER REGULATING
VALVE
VALVE
T
T
WATER OUTLET
WATER OUTLET
PRESS SENSING LINE
RFAC-50 WTR RGLTR
RFAC-51 WTR RGLTR
AMS-2 INTERCONNECTING PIPING
Abbreviations/Acronyms
COV
Cutoff Valve
EQL
EVAP
EXP
Expansion
FRZ
Freeze
LLSV
Liquid Line Solenoid Valve
PRESS
Pressure
RFSS
Refrigeration, Ship's Service
RGLTR
Regulator
STNR
Strainer
SUCT
Suction
TXV
Thermal Expansion Valve
V
Valve
Figure 2. Refrigeration System (Sheet 1 of 3)