TM 55-1925-273-10-1
0043 00
Table 1. Engine Room, Miscellaneous Systems (refer to figure 1) (continued)
Key
Control/Indicator
Function
4
Control Air Receiver
This receiver stores the control air for the vessel's control air system. Refer
to figure 3 for details.
5
PW-20, C.W. TO W.C.
This cutoff valve controls cold water to the water closet.
6
PW-21, C.W. TO W.C.
This cutoff valve controls cold water to the water closet.
7
Control Air Dryer
This air dryer removes moisture from the control air before it is routed to its
components. Refer to figure 4 for details.
8
Sewage Discharge
These valves enable sewage to be discharged from the vessel. Refer to
Pump 2 and Valves
figure 5 for details.
9
Cutoff Valve, Compressed Air
This valve secures the compressed air to the compressed air quick
disconnect valve beneath the EOS.
10
Regulator, Compressed Air
This regulates the pressure of the air available at the compressed air quick
disconnect valve beneath the EOS.
11
Quick Disconnect Valve
This valve permits attachment of a hose to the compressed air line beneath
the EOS.
12
FM-1, SEA SUCT, F.F. PMP.
This valve secures the raw water to the engine-driven fire pump.
Valve
13
Asw-17, SEA SUCTION S.W.
This strainer removes debris from the engine-driven fire pump's suction
COOLING
line.
14
Cutoff Valve for FF PMP
This valve secures pressure to the FF PMP SUCT STR DIFF PRESS gauge.
SUCT STR DIFF PRESS Gauge
15
Seachest Cutoff Valve
This valve secures raw water from the sea chest to the pump drive engine
and the bow thruster engine.
16
#1 SEWAGE DISCHARGE
This controls the motor for sewage discharge pump 1. Refer to figure 6 for
PUMP Motor Controller
details.
17
Sewage Discharge
This pump and its associated valves enable sewage to be discharged from
Pump 1 and Valves
the vessel. Refer to figure 7 for details.
18
SEWAGE PMP NO. 1
This gauge indicates the discharge pressure for sewage discharge pump 1.
DISCH PRESS Gauge
19
FF PMP SUCT STR DIFF
This gauge indicates the differential pressure across the firefighting pump
PRESS Gauge
suction strainer (figure 1, item 10).
20
Remote Indicator (Alarm)
Refer to figure 8 for details.
Assembly
21
PW-39, ENG. FILL CONN.
This provides a connection and a cutoff for a potable water hose.
STBD Valve
22
120V Emergency Distribution
This panel provides circuit protection for the engine room's emergency
Panel No. 1
electrical systems. Refer to figure 9 for details.
0043 00-2