TM 55-1925-273-10-1
0043 00
REMOTE INDICATOR (ALARM) ASSEMBLY
1
2
3
7
6
4
5
Figure 8. Remote Indicator (Alarm) Assembly
Table 8. Remote Indicator (Alarm) Assembly (refer to figure 8)
Key
Control/Indicator
Function
1
POWER ON Indicator
This illuminates to indicate that the OCM is operating.
2
OIL CONTENT EXCEEDS
This illuminates to indicate that the effluent oil content exceeds the
ALARM LIMIT Indicator
selected alarm limit.
3
OIL CONTENT PPM Display
This displays the effluent oil content in ppm.
4
70 PPM AT SEA Indicator
This illuminates to indicate that the 70 PPM (at sea) alarm limit is
selected.
5
PUSH TO CHANGE
This switch toggles between the 15 and 70 PPM alarm limit settings
ALARM LIMIT PPM Switch
when the alarm limit selector switch in the sampling/sensor assembly
is set to REMOTE.
6
15 PPM IN PORT Indicator
This illuminates to indicate that the 15 PPM (in port) alarm limit is
selected.
7
PUSH TO SILENCE Switch
Push this pushbutton switch to toggle the alarm silence function ON
and OFF.
0043 00-12