REVERSE OSMOSIS WATER PURIFICATION UNIT (ROWPU) GENERAL ARRANGEMENT
6
7
4 5
3
2
1
8
9
10
11
12
13
14
15
16
17
18
AMS-2
28
27
26
25
19
24 23
22
21 20
FWD
Figure 8. Reverse Osmosis Water Purification Unit (ROWPU) General Arrangement
Table 8. Reverse Osmosis Water Purification Unit (ROWPU) General Arrangement (refer to figure 8)
Key
Control/Indicator
Function
1
RO-V-9, ROWPU Auxiliary
This valve controls the fresh water supplied for ROWPU flushing during
Fresh Water Pressure Pump
maintenance cycles.
Supply
2
RO-PG-1-1, ROWPU 1
This gauge indicates pressure at the 5-micron filter inlet for ROWPU 1. It is
20-Micron Filter Outlet/
used with the high pressure pump inlet pressure gauge to determine
5-Micron
differential pressure across the 5-micron filter. Refer to table 2.