Tweet |
Custom Search
|
|
|
||
TM 55-1925-273-10-1
0053 00
Table 4. Fire Emergency Panel (refer to figure 4)
Key
Control/Indicator
Function
1
Hammer
The hammer is used to break the glass in the pull box, exposing the
operating T-Handle.
2
T-Handle
Pull this T-handle to actuate the engine room FM-200 system.
3
Fire Alarm Pull Station
Pull DOWN on this box to sound the fire alarm.
4
HVAC EMER STOP
When pressed, this secures the AMS 2 supply fan.
AMS 2 SPLY FAN
5
HVAC EMER STOP
When pressed, this switch secures the AMS 1 supply fan.
AMS 1 SPLY FAN
6
HVAC SYS EMER STOP
When pressed, this switch secures one pair of engine room exhaust and
ENG RM EXH FAN
supply fans.
ENG RM SPLY FAN
7
HVAC SYS EMER STOP
When pressed, this switch secures one pair of engine room exhaust and
ENG RM EXH FAN
supply fans.
ENG RM SPLY FAN
8
INTERIOR LIGHTING
This switch turns the interior lighting in the space ON and OFF.
SW Switch
9
EMER STOP FOR FO
This switch secures fuel oil transfer pump 1
XFER PUMP NO 1
10
EMER STOP FOR FO
This switch secures fuel oil transfer pump 2.
XFER PUMP NO 2
END OF WORK PACKAGE
00530053 00-5
00-5/6 blank
|
||