Custom Search
 
  
 
TM 55-1925-273-10-1
0058 00
Table 8. Towing Machine Operator Control Panel (refer to figure 8)
Key
Control/Indicator
Function
1
INBOARD TOW PIN
This switch is used to LOWER and RAISE the inboard STBD tow pin.
LOWER/RAISE Switch
2
OUTBOARD TOW PIN
This switch is used to LOWER and RAISE the outboard STBD tow pin.
LOWER/RAISE Switch
3
STBD MACH MAX CALBE
This indicator illuminates to indicate that less than 300 feet (91m) of cable
OFF BYPASS Pushbutton
remains on the STBD towing machine drum. Pressing the button overrides
Indicator
the cable off automatic shutdown.
4
STBD MACH CLUTCH
This indicator illuminates when the STBD towing machine clutch brake has
BRAKE SLIPPAGE Indicator
excessive slippage.
5
STBD SLIP ALARM Switch
This switch is used to cut off the slip alarm for the STBD towing machine.
6
SYSTEM READY Indicator
This indicator illuminates to indicate that the control station has electrical
power.
7
HYDRAULIC SYSTEM
This indicator illuminates to indicate low oil level and/or high oil tempera-
FAILURE Indicator
ture in the hydraulic system.
8
PORT MACH CLUTCH
This indicator illuminates when the PORT towing machine clutch brake has
BRAKE SLIPPAGE Indicator
excessive slippage.
9
PORT SLIP ALARM Switch
This switch is used to cut off the slip alarm for the PORT towing machine.
10
PORT MACH MAX CABLE
This indicator illuminates to indicate that less than 300 feet (91 m) of cable
OFF BYPASS Pushbutton
remains on the port towing machine drum. Pressing the button overrides the
Indicator
cable off automatic shutdown.
11
OUTBOARD TOW PIN
This switch is used to RAISE and LOWER the outboard PORT tow pin.
LOWER/RAISE Switch
12
INBOARD TOW PIN
This switch is used to RAISE and LOWER the inboard PORT tow pin.
LOWER/RAISE Switch
13
PRESSURE LOW Indicator
This indicator illuminates to indicate low hydraulic oil pressure.
14
LINE PULL METER
This meter indicates the load applied to the PORT towing machine.
15
ALARM SILENCE Pushbutton
This pushbutton is used to silence the alarm horn.
16
ALARM RESET Pushbutton
This pushbutton is used to reset the fault lights when a malfunction has been
corrected.
17
CABLE-OFF-METER
This gauge indicates the amount of cable payed out from the PORT towing
machine.
18
PAYOUT/HEAVE Lever
This lever controls the direction of the PORT towing machine.