EMERGENCY DIESEL GENERATOR CONTROL PANEL
5
2
3
4
1
WARNING
RESET
0
1
3
2
6
10
8
14
7
15
16
11
9
13
12
Figure 3. Emergency Diesel Generator Control Panel
Table 3. Emergency Diesel Generator Control Panel (refer to figure 3)
Key
Control/Indicator
Function
1
V Gauge
This gauge provides a digital readout of generator output voltage.
2
Voltage Adjust Rheostat
This rheostat adjusts the generator output voltage.
3
Hz Gauge
This gauge provides digital readout of generator output frequency in Hertz.
4
A Gauge
This gauge provides a digital readout of generator output current.
5
Engine Control Display
This display provides digital readout of various engine operating indicators.
6
Engine Control Display
This pushbutton scrolls through the various engine operating indicators
Pushbutton
displayed on the screen.
7
REVERSE POWER
This indicator illuminates to indicate a reversed power connection to the
Indicator
EDG.
8
EMERGENCY STOP
This indicator illuminates to indicate that an emergency stop has occurred.
Indicator
9
LOW OIL PRESSURE
This indicator illuminates to indicate that low lube oil pressure in the EDG
Indicator
engine caused the emergency stop.
10
HIGH COOLANT TEMP
This indicator illuminates to indicate that high coolant temperature in the
Indicator
EDG engine caused the emergency stop.