TM 55-1925-273-10-1
0072 00
8.
At 120V emergency distribution panel No. 1, ensure that the following circuit breakers are set to ON:
NOTE
If necessary to silence the fire alarm, obtain the key, unlock the fire and smoke alarm panel and
press the ALARM SILENCE pushbutton (TM 55-1925-292-14&P).
a.
FIRE DETECTION SYSTEM. (figure 5, item 1)
b.
E.O.T. SYSTEM. (figure 5, item 2)
c.
MONITOR SYSTEM CIRCUIT. (figure 5, item 3)
d.
REMOTE PROPULSION INDICATOR PANEL. (figure 5, item 4)
9.
OPEN the following fuel system valves:
a.
FO-20, F.O. SPLY TO STBD ME No. 1 (figure 6, item 1)
b.
FO-14, F.O. SERV CRSVR (figure 6, item 2)
c.
FO-15, F.O. SERV. SUCT. STBD (remote operator in the galley) (figure 6, item 3)
d.
FO-35, F.O. RTN TO DAY TK. STBD (figure 6, item 4)
e.
FO-34, F.O. RTN CRSVR (figure 6, item 5)
f.
Four Racor fuel supply cutoff valves (figure 7, item 1) and four Racor fuel discharge cutoff valves (figure 7, item 2)
located at the forward inboard corner of the engine.
10. OPEN the following coolant valves:
a.
Fwc-15, F.W. FR. KEEL CLR TO RED. GEAR No. 1 (figure 6, item 6)
b.
Fwc-13, F.W. FR. RED. GEAR No. 1 TO KEEL CLR (figure 6, item 7)
c.
Fwc-1, F.W. FR. KEEL CLR TO M.E. N0. 1 (figure 6, item 8)
4
1
2
3
Figure 5. 120V Emergency Distribution Panel No. 1
0072 00-4