Custom Search
 
  
 
TM 55-1925-273-10-1
0073 00
! CAUTION
Do not overfill the engine lube oil sump. Overfilling the sump can cause damage to the engine
oil seals.
3.
Align the electrical system, and start the transfer pump to fill the sump with lube oil by completing the following
actions:
a.
At the main switchboard in the EOS, verify that the ENGINE ROOM PWR PNL NO.1 circuit breaker (figure 3,
item 1) is set to ON.
b.
In the engine room on the aft bulkhead of the EOS, at 440V power panel No. 1, set the LUBE OIL TRANSFER
PUMP circuit breaker (figure 4 item 1) to ON.
c.
In the engine room, at the lube oil transfer pump motor controller:
(1)
Set the ON-OFF switch (figure 5 item 1) to ON.
(2)
Verify that the POWER AVAILABLE indicator (figure 5, item 2) energizes.
(3)
Press the motor controller START pushbutton (figure 5, item 3).
(4)
Verify that the MOTOR RUN indicator (figure 5, item 4) energizes.
2
1
Figure 3. Main Switchboard
0073 00-5


 