Figure 7. Lube Oil Purifier
NOTE
It takes 3 to 4 minutes for the bowl to reach its rated speed. When the bowl has reached its rated
speed, the motor run indicator will energize and the motor start indicator will go out.
d.
At the lube oil purifier, perform the following actions:
(1)
Check the revolution indicator disc (figure 7, item 6) and verify that the purifier is maintaining 65 to 78 r/min.
(2)
Open the needle valve (figure 7, item 7) to the fill bowl with water.
NOTE
The bowl is full when water enters and drains from the discharge chamber, as observed through
the opened inspection cover.
(3)
Open the inspection cover (figure 7, item 8) to verify that the bowl is filling with water.
(4)
When bowl is full, adjust the needle valve (figure 7, item 7) so that 1-3 drops per second of make-up water
enter the bowl for proper oil purification.