TM 55-1925-273-10-1
0079 00
6.
Set the OIL CONTENT MONITOR. circuit breaker (figure 11, item 2) in 120V distribution panel No. 4 to ON. The red
indicator (figure 14, item 1) on the OCM diverter valve position indicator (figure 14, item 2) will illuminate to signal
that the OCM has power available.
NOTE
With the OPERATION SELECTOR Switch A1S1 (figure 13, item 1) in the AUTO position, the
OCM will not operate until the pressure switch senses a pressure between 5 to 25 PSI (0.3 to 1.7
bar) at the OCM sample inlet. The OCM will automatically shut down if the pressure at the
OCM sample inlet falls below 5 PSI (0.3 bar).
7.
Position the OPERATION SELECTOR Switch A1S1 (figure 13, item 1) to AUTO.
NOTE
Placing the ALARM LIMIT (PPM) SELECTOR Switch A1S2 in the 15 PPM or 70 PPM posi-
tion disables the Remote Indicator Assembly.
8.
If the Remote Indicator Assembly (figure 15) is not used, set the ALARM LIMIT (PPM) SELECTOR Switch A1S2
(figure 13, item 2) to the 15 PPM position for OWS operation within 12 nautical miles of land or the 70 PPM position
for OWS operation outside 12 nautical miles of land. To utilize the Remote Indicator Assembly, set the ALARM LIMIT
(PPM) SELECTOR switch A1S2 to the REMOTE position.
4
2
3
1
OCM DIVERTER VALVE POSITION INDICATOR
DISCHARGE TO
DISCHARGE TO
OVER BOARD
OILY WASTE
HOLDING TANK
(GREEN)
(RED)
Figure 14. OCM Diverter Valve Position Indicator
0079 00-22


 