Custom Search
 
  
 
TM 55-1925-273-10-1
0082 00
NOTE
Heaters will cycle automatically to maintain the temperature set on the thermostats.
5.
Start all space heaters by completing the following actions:
a.
Set the ON-OFF switch (figure 13, item 1) to ON.
b.
Set the thermostat (figure 13, item 2) to the desired temperature.
6.
In the crew's mess, at the crew's mess fan coil motor controller R1-25-2, perform the following actions:
a.
Set ON-OFF switch (figure 14, item 1) to ON.
b.
Verify that the POWER AVAILABLE indicator (figure 14, item 2) illuminates.
c.
Press and release the START pushbutton (figure 14, item 3).
d.
Verify that the MOTOR RUN indicator (figure 14, item 4) illuminates.
7.
At the 01, 02, and pilothouse fan coil, R01-32-2 motor controller, perform the following actions:
a.
Set ON-OFF switch (figure 14, item 1) to ON.
b.
Verify that the POWER AVAILABLE indicator (figure 14, item 2) illuminates.
c.
Press and release the START pushbutton (figure 14, item 3).
d.
Verify that the MOTOR RUN indicator (figure 14, item 4) illuminates.
1
ON
OFF
2
POWER
4
AVAILABLE
MOTORRUN
1
3
START
STOP
2
RESET
ON
OFF
Figure 13. Space Heater
Figure 14. Single Speed Fan Motor Controller
0082 00-7


 


Privacy Statement - Copyright Information. - Contact Us