TM 55-1925-273-10-1
0086 00
2)
The alarm beeper will beep rapidly.
3)
After approximately 10 seconds, the LCD display (figure 2, item 1) will alternate between the maximum
boom angle alarm screen (figure 14) and the primary operating display screen (figure 10).
LOAD MOMENT INDICATOR (LMI) ACCESSING ADDITIONAL DISPLAY SCREENS
LOAD CHART IN USE DISPLAY SCREEN
1.
Perform the Load Moment Indicator (LMI) Operation procedure in this work package.
2.
Access the load chart in use display screen (figure 15) by pressing the down arrow button (figure 2, item 4) on the LMI
receiver panel (figure 2, item 2) once while in the primary operating screen (figure 10).
3.
The load chart in use display screen (figure 15) will display the information contained in table 2.
4.
The display will automatically default to the primary operating screen (figure 10) after approximately 10 seconds.
1
5
01: Appleton Marine EB10-35-15 Main  Laser=OKAY
MAIN Load  POL=3  Boom Length= 25.0 ft
4
2
3
Figure 15. Load Chart in Use Screen
Table 2. Load Chart In Use (refer to figure 15)
Item No.
Display
Information Displayed
1
01
Details the current programmed load chart
2
MAIN
Is the selected winch
3
POL
The parts of line in use on the winch
4
Boom Length
Indicated total length of boom in use
5
Laser Condition Indicates operating condition of the laser. Normal condition is OKAY.
TRANSMITTER SIGNAL STRENGTH DISPLAY SCREEN
1.
Perform the Load Moment Indicator (LMI) Operation procedure in this work package.
2.
Access the transmitter(s) signal strength display screen (figure 16) by pressing the down arrow button (figure 2, item 4)
on the LMI receiver panel (figure 2, item 2) twice while in the primary operating display screen (figure 10).
0086 00-6


 