0086 00
SET MAXIMUM TIP HEIGHT ALARM
1.
Perform the Load Moment Indicator (LMI) Operation procedure in this work package.
2.
From the primary operating display screen (figure 10), press the MODE button (figure 2, item 3) and the down arrow
button (figure 2, item 4) on the LMI receiver panel (figure 2, item 2) to display the change min/max presets & select
sensor display screen (figure 19).
3.
Press the down arrow button (figure 2, item 4) on the LMI receiver panel (figure 2, item 2) and scroll through the
selections until TIP is highlighted.
4.
Press the MODE button (figure 2, item 3) and the down arrow button (figure 2, item 4) on the LMI receiver panel
(figure 2, item 2) once to reach the tip height alarm menu screen (figure 28). If SET MAX is not already
highlighted, press the up arrow button (figure 2, item 5) or the down arrow button on the LMI receiver panel until
SET MAX is highlighted.
5.
Press the MODE button (figure 2, item 3) and the down arrow button (figure 2, item 4) on the LMI receiver panel (figure
2, item 2) to reach the maximum tip height alarm setting screen (figure 29).
6.
Press the down arrow button (figure 2, item 4) or the up arrow button (figure 2, item 5) on the LMI receiver panel (figure
2, item 2) until the readout (figure 29, item 1) displays the tip height value desired.
NOTE
Once saved, the settings will remain in effect even after the unit is powered off. If the settings are
not saved, they will not remain in effect the next time the unit is powered up.
7.
Save the setting by pressing the MODE button (figure 2, item 3) and the down arrow button (figure 2, item 4) on the
LMI receiver panel (figure 2, item 2) once. The saving screen (figure 9) will appear briefly. Once the save is complete,
the saving screen will be replaced by the tip height alarm menu screen (figure 28).
8.
Press and hold the MODE button (figure 2, item 3) and push the up arrow button (figure 2, item 5) on the LMI receiver
panel (figure 2, item 2) twice to return to the primary operating display screen (figure 10).
<SET MIN>
SET MAX
Figure 28. Tip Height Alarm Menu Screen
1
Set
MAIN Tip Height
MAX:  90 ft
Accept by Mode , Change by
buttons.
Figure 29. Maximum Tip Height Alarm Setting Screen
0086 00-13


 