TM 55-1925-273-10-1
0097 00
6.
On the aft engine room bulkhead, at the reduction gear 1 fresh water cooling pump motor controller, perform the
following actions:
a.
Press the STOP pushbutton (figure 3, item 1).
b.
Verify that the MOTOR RUN indicator (figure 3, item 2) goes out.
c.
Set the ON-OFF switch (figure 3, item 3) to the OFF position
d.
Verify that the POWER AVAILABLE indicator (figure 3, item 4) goes out.
ON
3
OFF
4
POWER
AVAILABLE
MOTOR RUN
2
START
STOP
1
RESET
Figure 3. Fresh Water Cooling Pump Motor Controller
7.
CLOSE the following valves:
a.
FO-20, F.O. SPLY TO STBD ME No. 1 (figure 4, item 1)
b.
FO-14, F.O. SERV CRSVR (figure 4, item 2)
c.
FO-15, F.O. SERV. SUCT. STBD (figure 4, item 3) (remote operator in the galley)
d.
FO-35, F.O. RTN TO DAY TK. STBD (figure 4, item 4)
0097 00-3