Custom Search
 
  
 
TM 55-1925-273-10-1
0100 00
p.
OB-14, C.O.V. OILY BILGE PMP. SUCT. (figure 6, item 16)
q.
OB-13, OWT TO XFR PUMP SUCTION (figure 6, item 17)
r.
OB-8, OILY BILGE PMP DISCH. TO OILY WST.STOR. TK (figure 6, item 18)
s.
OB-17, OILY WATER TANK INLET (figure 6, item 19)
2.
To secure the OWS piping, CLOSE the following valves:
a.
OWS-4, OCM 3-WAY DIVERTER (figure 6, item 20), operator to LOCAL/SHUT
b.
OWS-2, OWS DISCHARGE (figure 6, item 21)
c.
OWS-3, OWS PUMP DISCHARGE (figure 6, item 22)
d.
GS-74, OWS BACKFLUSH INLET SOLENOID (figure 6, item 23)
e.
OWS-5, OWS DISCHARGE (figure 6, item 24)
f.
OWS-7, BACKFLUSH WTR TO PRESS RDCR (figure 6, item 25)
g.
OWS-8, BACKFLUSH WTR FROM PRESS RDCR (figure 6, item 26)
h.
OWS-10, OWS RECIRCULATING COV (figure 6, item 27)
3.
To secure the OCM piping, CLOSE the following valves:
a.
OCM-1, OCM NOZZLE SAMPLER COV (figure 6, item 28)
b.
OCM-4, OCM INLET (figure 6, item 29)
c.
OWS-1, OWS MANUAL BACKFLUSH (figure 6, item 30)
d.
OWS-6, OWS PITOT SAMPLE (figure 6, item 31)
e.
OWS-9, BACKFLUSH WTR PRESS RDCR BYPASS (figure 6, item 32)
f.
OCM-2, OCM BACKFLUSH WATER (figure 6, item 33)
g.
OCM-3, OCM SAMPLING VALVE (figure 6, item 34)
SECURE THE BILGE/BALLAST PIPING SYSTEM
To secure the bilge/ballast piping system, CLOSE the following valves:
1.
BB-12, BLST. TK. No. 1 SUCT. COV (figure 7, item 1)
2.
BB-25, BLST MANF TO PMPS OUTLT (figure 7, item 2)
3.
BB-34, B/B PMP No. 1 OVBD DISCH. (figure 7, item 3)
4.
BB-32, B/B PMP No.2 OVBD DISCH (figure 7, item 4)
5.
BB-29, B/B PMP No. 1 BILGE SUCT. (figure 7, item 5)
6.
BB-30, B/B PMP. No. 2 BILGE SUCT. (figure 7, item 6)