TM 55-1925-273-10-1
0103 00
2
1
Figure 3. Lube Oil Purifier
SECURE THE LUBE OIL ELECTRICAL SYSTEM
1.
STOP the lube oil transfer pump by completing the following actions at the lube oil transfer pump motor controller:
a.
Press the STOP pushbutton (figure 4, item 1).
b.
Verify that the MOTOR RUN indicator lamp (figure 4, item 2) goes out.
c.
Set the ON/OFF switch (figure 4, item 3) to the OFF position.
d.
Verify that the POWER AVAILABLE indicator (figure 4, item 4) goes out.
2.
At 440V power panel No. 1, set the LUBE OIL TRANSFER PUMP. (figure 5, item 1) circuit breaker to OFF.
0103 00-4