At the fuel filter/water separator control panel, set the OFF/ON (figure 2, item 1) switch OFF.
1
Figure 2. Fuel Filter/Water Separator Filter Control Panel
3.
To secure the fuel oil transfer piping, verify that the following valves are CLOSED:
a.
F.O-3, DK. FILL CONN (figure 3, item 1)
b.
FO-4, DK. FILL CONN (figure 3, item 2)
c.
FO-5, F.O.DAY TK EMERG FILL (figure 3, item 3)
d.
FO-6, C.O.V. - F.O. XFER PMP N0.1 SUCTION (figure 3, item 4)
e.
FO-8, C.O.V. - F.O. XFER PMP No.1 DISCHARGE (figure 3, item 5)
f.
FO-7, C.O.V. - F.O. XFER PMP No.2 SUCTION (figure 3, item 6)
g.
FO-9, C.O.V.- F.O. XFER PMP No.2 DISCHARGE (figure 3, item 7)
h.
FO-17, F.O. FLTR / WATER SEP OUTLET. COV (figure 3, item 8)
i.
FO-42, F.O. FLTR / WATER SEP BYPASS COV (figure 3, item 9)
j.
FO-16, F.O. FLTR / WATER SEP INLET. COV (figure 3, item 10)
k.
FO-11, F.O. TO E.D.G. DAY TK (figure 3, item 11)
0104 00-2


 