TM 55-1925-273-10-1
0105 00
4.
At the hot potable water recirculating pump motor controller, verify that the POWER AVAILABLE indicator (figure 2,
item 3) goes out.
5.
In AMS 2, at the potable water pump 1 and 2 motor controllers:
a.
Press the STOP pushbuttons (figure 4, item 1).
b.
Verify that the MOTOR RUN indicators (figure 4, item 2) go out.
c.
Set the ON-OFF switches (figure 4, item 3) to OFF.
d.
Verify that the POWER AVAILABLE indicators (figure 4, item 4) go out.
3
ON
OFF
4
POWER
2
AVAILABLE
MOTORRUN
START
STOP
1
LOCAL REMOTE
RESET
Figure 4. Potable Water Pump 1 and 2 Motor Controller
6.
At the 440V power panel No. 5, set the following circuit breakers to OFF:
a.
POTABLE WATER PUMP No. 1. (figure 5, item 1)
b.
POTABLE WATER PUMP No. 2. (figure 5, item 2)
7.
At the 120V distribution panel No. 3, set the MAIN DECK DRINKING FOUNTAIN. circuit breaker (figure 6, item 1)
to OFF.
8.
At the 120V distribution panel No. 2, set the following circuit breakers to OFF:
a.
01 LEVEL DRINKING FOUNTAIN. (figure 7, item 1).
b.
PILOT HOUSE DRINKING FOUNTAIN & COFEE MAKER. (figure 7, item 2).
0105 00-3