TM 55-1925-273-10-1
0107 00
d.
Dehydrator outlet valve (figure 1, item 7)
e.
Dehydrator inlet valve (figure 1, item 1)
f.
Equalizing line valve (figure 1, item 8)
g.
Water regulator valve actuating line valve (figure 1, item 9)
h.
Compressor suction valve (figure 1, item 2)
i.
Dehydrator bypass valve (figure 1, item 10)
j.
Purge valve (figure 1, item 11)
k.
Charge and drain valve (figure 1, item 12)
SECURE CONDENSER COOLING WATER
1.
Secure general service piping by placing the following valves in the CLOSED position:
a.
For air conditioning condensing unit 1:
(1)
GS-33, A/C COND No.1 SPLY (figure 2, item 1), air conditioning condenser 2 supply
(2)
GS-36, WTR RGLTR COV (figure 2, item 2), water regulator inlet
b.
For air conditioning condensing unit 2:
(1)
GS- 34, A/C COND No.2 SPLY (figure 2, item 3), air conditioning condenser 1 supply
(2)
GS-37, WTR RGLTR COV (figure 2, item 4), water regulator inlet
c.
For reefer condensing unit 1:
(1)
GS-38, RETR COND No.1 SPLY (figure 2, item 5), reefer condenser 2 supply
(2)
GS-48, WTR RGLTR COV (figure 2, item 6), water regulator inlet
d.
For reefer condensing unit 2:
(1)
GS-39, RETR COND No.2 SPLY (figure 2, item 7), reefer condenser 1 supply
(2)
GS-49, WTR. RGLTR COV (figure 2, item 8), water regulator inlet
0107 00-3
|
||